A non-return valve - part of the rotating equipment protection system - is placed in extraction and/or induction steam piping to prevent back-flow of steam and/or water into the turbine after a unit trip.
Gimpel offers a "free-swing" design that closes when a flow reversal is sensed across the valve. Pneumatic and hydraulic operating cylinders are available.